Glocuse Point-of-Care analyser
- Latest Biosensor Technology
- Low Blood Volume Required
- Fast, Simple 2-step Testing
- Fast Testing Time of 10 seconds
- Large LCD Display* Easy Operation
- Reading rand of 1.7 - 30.6 mmol/L
- 10 Result Memory
- Code Chip Calibration
Uric Acid Point-of-Care analyser
- Fast, simple 2 step testing
- Code chip calibration
- One button memory recall
- Fast capillary action wicks sample into the test strip
- Small blood sample
- Biosensor technology
- Results in 30 seconds
- Reading Range of 0.176 - 1.170 mmol/L
|
Lactate Point-of-Care analyser
- Advance Biosensor Tests Strips
- Low Blood Volume Required
- Fast Siphoning Action
- Fast Testing Time of 45 seconds
- Large LCD Display* Date and Time Stamped Memory
- Easy operation* Small size
- Reading range of 0.7 - 22.2 mmol/l
- PC Interface
- Enables more Effiecent Training Plans
 

|

Liqui-Stat Point-of-care analyser
- A first true wet-chemistry point-of-care analyser for the diagnostic market

- Employs the use of special patented pre-filled cuvettes
- The design of the cuvettes allows the testing of all routine chemistries
plus a wide range of specialized assays
- Calibration and QC data is stored
- Touch screen LED interface
- Results comparable to large laboratory type equipment
- Test performance is as simple as 1-2-3
- sample is introduced into pre-filled assay cuvette
- the sample-reagent mixture is mixed
- and incubation and measurement is completed within analyser

Screw Cap Capillary Blood Collection Systems:
- Available for all examinations
- Screw Plug Technique avoids aerosol effect and therefore reduces risk of injection
- Suitable for Bar Codes
- Interior surface evenly coated
- Coated capillary of fracture-proof, chemically neutral plastics
- Available in a range of different sizes to suite departmental and analyser requirements
- Colour coded for identification of blood collection devices
Twist & Turn Click Clack Capillary Blood Collection Systems:
- Available for all examinations
- Twist & turn closure technique
- Interior surface evenly coated
- Coated capillary of fracture-proof, chemically neutral plastics
- Available in a range of different sizes to suite departmental and analyser requirements
- Colour coded for identification of blood collection devices
- Embossed numerical graduations provide an easy means to track specimen collection rate.
PAEDIATRIC ESR SYSTEM
- Screw Plug Technique avoids aerosol effect and therefore reduces risk of injection
- Includes Sedimentation pipette
- Suitable for Bar Codes
- Interior surface evenly coated
- Coated capillary of fracture-proof, chemically neutral plastics

|
PLASTIC BLOOD GAS CAPILLARIES
- Blood Gas Capillaries are made of fracture-proof, chemically neutral plastics therefore avoid risks of injuries or infections
during the blood collection procedure
- The capillaries are evenly coated with 50 l.U. balanced heparin
- They can be sealed with closing caps
- The capillaries are available in sizes ranging from 5 µl to 285 µl
- Special sizes can be manufactured according your requirements
- Capillaries up to a length to 120 mm are packed in dispenser tubes. Capillaries longer than 120 mm are packed in poly bags.
- One packing unit consists of 10 x 100 pieces.
ACCESSORIES FOR CAPILLARY BLOOD COLLECTION
In addition to the blood gas accessories, the following accessories are available:
- closing caps
- mixing wires
- mixing magnets
- luer adaptors
- wax sealing plates
- sterile lancets
- capillary holders.
BLOOD GAS SAMPLING SYSTEM A-K-FIX & LUER CANNULA
- This Blood Gas Sampling Systems serve as an arterial extraction
device for
pH / Blood gas
Electrolytes
Co-oximetry
Metabolic analysis
- The devices are coated with approx. 100 I.U. balanced lithium heparin.
- For single use only
- Due to the AUTOSTOP action, the blood flow stops automatically
- One test set consists of 1 luer adaptor, 2 closing caps and a
heparinised plastic capillary with volume 200 µl, outer diameter 2,35 mm and length 130 mm.
- The capillary is made of fracture proof, gas impermeable material
- The test set will be supplied sterile and packed single.
BLOOD GAS SAMPLING SYRINGES
- The Blood Gas Sampling Syringes serve as an arterial extraction device for pH / Blood Gas, Electrolytes, Co-oximetry and
- Metabolic analysis.
- The syringes are coated with approx. 50 I.U.
balanced heparin
- For single use only
- Supplied in individual sterile packages
- Available in 1 ml or 2 ml sizes, the low volume ideal for preventing the introduction of air bubbles in the syringes which can adversely affect blood gas results
|

COMFORT SAMPLER—BLOOD GAS COLLECTION DEVICE
- Capillary type blood gas collection device ideal for Paediatric; Neonatal or Geriatric patients or any patient presenting with a difficult bleed
- The Comfort sampler consists of 2 capillaries each coated with Balanced heparin to prevent clotting and so provide accurate results
- Capillary action allows samples to be collected with minimal effort and holds a total of 240µl, enough sample to be analysed on most blood gas analysers
- The capillaries are protected by a plastic housing, this prevents any transfer of heat from the fingers to the sample and confines any breakages reducing the risk of infection and contamination
- Micro-thin needles reduce patient trauma and discomfort
and reduce the risk of patient haematoma
- Integrated needle protector to improve user safety

Opti CCA Blood Gas Analyser
- Portable critical care analyser employing a single use cartridge
- Cassettes have different configurations for operator convenience
and can measure the following parameters -pH pCO2 -pO2 -Saturated O2
-Glucose -Chloride
and calculates another 15 parameters
- Cassesttes are stored at room temperature
- Easy to use, step wise procedure displayed on LCD screen
- Barcode technology ensures all components used are within expiry and
informs analyser of calibration values and cassettes configuration
- Sample aspiration is automatic from either a syringe or capillary
- The sample measurinf chamber is pre-heated to 37C to allow improved
accuracy of results
- No wastage; when the instrument is not in use - no gas or fluidsare used
therefore reducing costs
- Maintenance is minimal, no electrodes or solutions to refill or monitor
- Results are displayed on screen and printed on built-in-thermal printer
|
Opti R Blood gas Analyser
Specifications Are as per Opti CCA analyser above with the following exceptions
- Reusable cassette measuring a total of 50 patient samples
- Cassettes configuration is pH; pCO2; p02; Saturated O2;
Total haemoglobin; Sodium; Potasium & Ionised Calcium
- Analyser is always in a "Ready to analyse" state which is important in stat situations
- Fluid pack contains Calibration and wash solutions to ensure te integrity of the cassette
- The waste compartment is also in the fluid pack and contains Hydrogel
which converts all biohazardous material into a gel thus preventing any
contamination and leakages
- 3 levels of Quality controls are also included in the reagent pack and are
measured automatically and are not counted as samples.
Opti Lion Elecrtrolyte Analyser
- Portable electrolyte analyser employing a single use cassette
- Analytes measured include: Sodium; Potassium;
Chloride; Ionised Calcium and pH
- Lab Accurate results in less than 2 minutes
- Large Colour touch screen display provides graphical step wise
procedure for ease of operation
- Cassettes are stored at room temperature
- Sample aspiration is automatic from either a syringe or capillary
for whole blood samples or from serum samples
- Maintenance is minimal, no electrodes or solutions to refill or monitor
- Results are displayed on screen and printed on built-in thermal printer
- Up to 300 sample and QC results results are stored and are easily retrieved.

Opti Touch Screen Blood Gas Analyser
Specifications are as per Opti CCA analyser above with the following expections:
- Large Touch Screen display provides graphical step
wise procedure for ease of operation
- Large Colourful icons make functions easy to identify
- Up to 200 results are stored and easily idenitified in page
search with date and sample identification
- The built-in flash port allows all control results and patient data
with reulsts to be downloaded into a flash-card for easy import onto
QC managers computer and allows tracking of results for billing procedures
|
Back to Top |
|