Katmedical "Commited to Care"




Apex Bio

Glocuse Point-of-Care analyser

  • Latest Biosensor Technology
  • Low Blood Volume Required
  • Fast, Simple 2-step Testing
  • Fast Testing Time of 10 seconds
  • Large LCD Display* Easy Operation
  • Reading rand of 1.7 - 30.6 mmol/L
  • 10 Result Memory
  • Code Chip Calibration

 

Uric Acid Point-of-Care analyser

  • Fast, simple 2 step testing
  • Code chip calibration
  • One button memory recall
  • Fast capillary action wicks sample into the test strip
  • Small blood sample
  • Biosensor technology
  • Results in 30 seconds
  • Reading Range of 0.176 - 1.170 mmol/L

Lactate Point-of-Care analyser

  • Advance Biosensor Tests Strips
  • Low Blood Volume Required
  • Fast Siphoning Action
  • Fast Testing Time of 45 seconds
  • Large LCD Display* Date and Time Stamped Memory
  • Easy operation* Small size
  • Reading range of 0.7 - 22.2 mmol/l
  • PC Interface
  • Enables more Effiecent Training Plans

 

 

Audit Diagnostics

Liqui-Stat Point-of-care analyser

  • A first true wet-chemistry point-of-care analyser for the diagnostic marketLiqui-stat
  • Employs the use of special patented pre-filled cuvettes
  • The design of the cuvettes allows the testing of all routine chemistries
    plus a wide range of specialized assays
  • Calibration and QC data is stored
  • Touch screen LED interface
  • Results comparable to large laboratory type equipment
  • Test performance is as simple as 1-2-3
  1. sample is introduced into pre-filled assay cuvette
  2. the sample-reagent mixture is mixed
  3. and incubation and measurement is completed within analyser

 

Sanguis Counting

Screw Cap Capillary Blood Collection Systems:

  • Available for all examinations
  • Screw Plug Technique avoids aerosol effect and therefore reduces risk of injection
  • Suitable for Bar Codes
  • Interior surface evenly coated
  • Coated capillary of fracture-proof, chemically neutral plastics
  • Available in a range of different sizes to suite departmental and analyser requirements
  • Colour coded for identification of blood collection devices

Twist & Turn Click Clack Capillary Blood Collection Systems:

  • Available for all examinations
  • Twist & turn closure technique
  • Interior surface evenly coated
  • Coated capillary of fracture-proof, chemically neutral plastics
  • Available in a range of different sizes to suite departmental and analyser requirements
  • Colour coded for identification of blood collection devices
  • Embossed numerical graduations provide an easy means to track specimen collection rate.

PAEDIATRIC ESR SYSTEM

  • Screw Plug Technique avoids aerosol effect and therefore reduces risk of injection
  • Includes Sedimentation pipette
  • Suitable for Bar Codes
  • Interior surface evenly coated
  • Coated capillary of fracture-proof, chemically neutral plastics

 

Syringes

 

PLASTIC BLOOD GAS CAPILLARIES


  • Blood Gas Capillaries are made of fracture-proof, chemically neutral plastics therefore avoid risks of injuries or infections
    during the blood collection procedure
  • The capillaries are evenly coated with 50 l.U. balanced heparin
  • They can be sealed with closing caps
  • The capillaries are available in sizes ranging from 5 µl to 285 µl
  • Special sizes can be manufactured according your requirements
  • Capillaries up to a length to 120 mm are packed in dispenser tubes. Capillaries longer than 120 mm are packed in poly bags.
  • One packing unit consists of 10 x 100 pieces.

ACCESSORIES FOR CAPILLARY BLOOD COLLECTION

In addition to the blood gas accessories, the following accessories are available:

  • closing caps
  • mixing wires
  • mixing magnets
  • luer adaptors
  • wax sealing plates
  • sterile lancets
  • capillary holders.

 

BLOOD GAS SAMPLING SYSTEM A-K-FIX & LUER CANNULA

  • This Blood Gas Sampling Systems serve as an arterial extraction
    device for
    pH / Blood gas
    Electrolytes
    Co-oximetry
    Metabolic analysis
  • The devices are coated with approx. 100 I.U. balanced lithium heparin.
  • For single use only
  • Due to the AUTOSTOP action, the blood flow stops automatically
  • One test set consists of 1 luer adaptor, 2 closing caps and a
    heparinised plastic capillary with volume 200 µl, outer diameter 2,35 mm and length 130 mm.
  • The capillary is made of fracture proof, gas impermeable material
  • The test set will be supplied sterile and packed single.

BLOOD GAS SAMPLING SYRINGES

  • The Blood Gas Sampling Syringes serve as an arterial extraction device for pH / Blood Gas, Electrolytes, Co-oximetry and
  • Metabolic analysis.
  • The syringes are coated with approx. 50 I.U.
    balanced heparin
  • For single use only
  • Supplied in individual sterile packages
  • Available in 1 ml or 2 ml sizes, the low volume ideal for preventing the introduction of air bubbles in the syringes which can adversely affect blood gas results

OptiMedical

COMFORT SAMPLER—BLOOD GAS COLLECTION DEVICE

  • Capillary type blood gas collection device ideal for Paediatric; Neonatal or Geriatric patients or any patient presenting with a difficult bleed
  • The Comfort sampler consists of 2 capillaries each coated with Balanced heparin to prevent clotting and so provide accurate results
  • Capillary action allows samples to be collected with minimal effort and holds a total of 240µl, enough sample to be analysed on most blood gas analysers
  • The capillaries are protected by a plastic housing, this prevents any transfer of heat from the fingers to the sample and confines any breakages reducing the risk of infection and contamination
  • Micro-thin needles reduce patient trauma and discomfort
    and reduce the risk of patient haematoma
  • Integrated needle protector to improve user safety

 

 

Opti CCA Blood Gas Analyser

  • Portable critical care analyser employing a single use cartridge
  • Cassettes have different configurations for operator convenience
    and can measure the following parameters -pH pCO2 -pO2 -Saturated O2
    -Glucose -Chloride
    and calculates another 15 parameters
  • Cassesttes are stored at room temperature
  • Easy to use, step wise procedure displayed on LCD screen
  • Barcode technology ensures all components used are within expiry and
    informs analyser of calibration values and cassettes configuration
  • Sample aspiration is automatic from either a syringe or capillary
  • The sample measurinf chamber is pre-heated to 37C to allow improved
    accuracy of results
  • No wastage; when the instrument is not in use - no gas or fluidsare used
    therefore reducing costs
  • Maintenance is minimal, no electrodes or solutions to refill or monitor
  • Results are displayed on screen and printed on built-in-thermal printer

 

 

 

Opti R Blood gas Analyser

Specifications Are as per Opti CCA analyser above with the following exceptions

  • Reusable cassette measuring a total of 50 patient samples
  • Cassettes configuration is pH; pCO2; p02; Saturated O2;
    Total haemoglobin; Sodium; Potasium & Ionised Calcium
  • Analyser is always in a "Ready to analyse" state which is important in stat situations
  • Fluid pack contains Calibration and wash solutions to ensure te integrity of the cassette
  • The waste compartment is also in the fluid pack and contains Hydrogel
    which converts all biohazardous material into a gel thus preventing any
    contamination and leakages
  • 3 levels of Quality controls are also included in the reagent pack and are
    measured automatically and are not counted as samples.

Opti Lion Elecrtrolyte Analyser

  • Portable electrolyte analyser employing a single use cassette
  • Analytes measured include: Sodium; Potassium;
    Chloride; Ionised Calcium and pH
  • Lab Accurate results in less than 2 minutes
  • Large Colour touch screen display provides graphical step wise
    procedure for ease of operation
  • Cassettes are stored at room temperature
  • Sample aspiration is automatic from either a syringe or capillary
    for whole blood samples or from serum samples
  • Maintenance is minimal, no electrodes or solutions to refill or monitor
  • Results are displayed on screen and printed on built-in thermal printer
  • Up to 300 sample and QC results results are stored and are easily retrieved.

Opti Touch Screen Blood Gas Analyser

Specifications are as per Opti CCA analyser above with the following expections:

  • Large Touch Screen display provides graphical step
    wise procedure for ease of operation
  • Large Colourful icons make functions easy to identify
  • Up to 200 results are stored and easily idenitified in page
    search with date and sample identification
  • The built-in flash port allows all control results and patient data
    with reulsts to be downloaded into a flash-card for easy import onto
    QC managers computer and allows tracking of results for billing procedures

Back to Top